Access control reader

Access control reader
FingerTec R2c in the UAE
The FingerTec R2c is a access control reader from FingerTec, using fingerprint, rfid card and pin or password as the credential. It connects over RS-485. It runs with Managed through the master terminal under Ingress / TCMS V3.
- Manufacturer
- FingerTec
- Category
- Access control reader
- Credentials
- Fingerprint · RFID card · PIN or password
- Connectivity
- RS-485
Where this unit fits
- Adding a second read point so one door records both entry and exit
- Cost-effective exit reader with no independent processing or storage
- Enrolment happens only on the master
- Pairs with an R2 or Q2i to make a complete in / out biometric door
Full specification
Taken from the manufacturer's own datasheet, with the source linked.
| Brand / Manufacturer | FingerTec |
|---|---|
| Device type | Fingerprint and card SLAVE reader (exit reader) for R2 and Q2i master terminals |
| Verification methods | Fingerprint (1:N) and card only. No keypad, no password, no 1:1 |
| Capacity | None of its own. All templates and logs live in the master terminal |
| Display | No LCD, LED indicators only |
| Communication | RS485 to the master terminal only |
| Access control | Provides the second (exit) read point so the master controls IN and OUT. The lock relay and alarm are handled by the master |
| Operating temp. | 0 to 45 C, humidity 20-80% |
| Dimensions | 64 x 42 x 135 mm |
| Power supply | Supplied and managed by the master terminal |
| Software | Managed through the master terminal under Ingress / TCMS V3 |
| HOW MASTER AND SLAVE DIFFER | The master (R2, Q2i, Kadex) holds the user database and transaction log, has the display and menu for enrolment, drives the lock relay and alarm, and carries the network link to Ingress. The slave (R2c, i-Kadex) has no database, no log, no network port and no enrolment. It captures a credential on the other side of the door and passes it to the master, which decides, logs and opens. |
Where this data comes from
Every specification here is checked against the manufacturer's own document before it goes live.
Common questions
- How does the FingerTec R2c connect?
- It supports RS-485. In UAE installations we normally run it on wired Ethernet, with Wi-Fi kept as the fallback where cabling is impractical.
- What software runs the FingerTec R2c?
- Managed through the master terminal under Ingress / TCMS V3. We connect the attendance data through to payroll and produce a WPS-ready export, so the punches become a payable file rather than a report someone has to retype.
- Do you install and support the FingerTec R2c across the UAE?
- Yes. We supply, install, configure, train your team and support it across Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah, Fujairah and Umm Al Quwain. Call +971 54 707 9900 for a fixed written quote.
Is the FingerTec R2c the right fit for your site?
Send us your headcount and how many doors you need covered. We come back with the right specification and a fixed written quote, free of charge.
Request your free quote
A specialist replies within 2 working hours.